Minimum Order Quantity | 1 Piece |
Model Name/Number | Extend XT |
Ventilation Modes | PEEP,CPAP,VCV-NIV,PCV-NIV,SIMV-NIV,PSIMV-NIV,PSV-NIV and PS-PEEP NIV |
Tidal Volume | 20-2000 ml |
Respiratory Rate | 5-100 bpm |
RSBI (Rapid Shallow Breathing Index) | 0.1 |
Brand | Air Liquide |
Plateau Pressure | Automatic measurement in VCV |
Country of Origin | Made in India |
Patient Age Group | Adult, Paediatric, Neonatal |
Mounting Type | ICU |
Touch Screen Present | Yes |
eXtend XT has been developed to enhance a wide range of treatments for critical-care patients. Its user-friendly interface and wide screen make it easy and safe to use. EXtendXT has a large range of monitoring capacities like lung recruitability evaluation to assist in the diagnosis and decision-making process for the most critical patients.
Integration into intensive care unit
Patient safety
Advanced patient monitoring and data recording
A diagnosis tool
Trating all types of patients
Considering all treatment strategies
eXtend XT has been developed to enhance a wide range of treatments for critical-care patients. Its user-friendly interface and wide screen make it easy and safe to use. EXtendXT has a large range of monitoring capacities like lung recruitability evaluation to assist in the diagnosis and decision-making process for the most critical patients.Critical care
Patients from newborns to adults Invasive and non-invasive ventilation: automatic leak compensation
Complete range of ventilation modes including VCV, PSV, Duo-Levels, APRV, MRV ( ALMS innovation), PRVC.
Functional exploration
15-inch screen for comfortable reading
Automatic compliance and resistance measurement Total PEEP, Auto-PEEP, plateau pressure
Display of four simultaneous curves: realtime curves and loop curves Weaning index: P0.1, RR/Vt
Minimum Order Quantity | 1 Piece |
Tidal Volume | 100 to 2000 ml |
Brand | Airliquide |
Model Name/Number | Osiri S3 |
Ventilation Modes | Volume Control / Assisted Volume Control Mechanical |
Patient Age Group | Neonatal, Adult |
Dimensions (L x H x D) | 250 x 210 x 170 mm |
Weight | 5 kg |
Individual Gas Consumption | 2.8 to 6 bar |
Internal Power Supply | Pack of NiMh Batteries |
Battery Life | 6 h minimum, 14 h usually |
Charging Time | 3 hours |
Voltage | 100 - 230 V |
CMV-ACMV Peak Flowrate | 100 L/min |
PS-PEEP Peak Flowrate | 130 L/min |
Applications | Adult - Child Emergency - Transport - Intra-Hospital Transfer - Recovery |
Breathing Rate | 6 to 40 c/min |
Inspiratory Trigger | Off, -0.5 to 4 cmH2O |
CMV/ACMV Position | 100% |
Minimum Order Quantity | 1 Piece |
Tidal Volume | 50 mL to 2000 mL |
Brand | Air Liquide |
Model Name/Number | VEGA |
Ventilation Modes | CPAP, PSV, PSV-NIV, VCV, PCV, SIMV, P-SIMV, PRVC, PRVC-SIMV, HFOT |
Respiratory Rate | 1- 60 BMP |
Patient Age Group | Neonatal |
Plateau (%) | 80% |
Mounting Type | ICU |
Touch Screen Present | Yes |
Country of Origin | Made in India |
Battery backup | 1 Hour |
Ventilator Dimension | 373 x 439 x 300 ( W X D X H) mm |
ventilator weight | 20 kg |
FiO2 Range | 21 to 100% |
Brand | BPL |
Model Name/Number | Leoni Plus |
Patient Age Group | Neonatal, Paediatric |
Country of Origin | Made in India |
Dimension (W x D x H) | 30.5 x 38.5 x 39 cm |
Weight | 22 kg (including HFOV module) |
Power Supply | 100 - 240VAC,50/60 Hz |
Battery-powered Operation | 200 min conventional,60 min HFOV |
HFOV Frequency Setting Range | 5 - 20 Hz |
O2 Measurement Monitoring | 21% - 100% |
HFOV Oscillation Setting Range | 5 - 100 mbar |
Parameter Peak Inspiration Pressure | 4 - 60 mbar |
Parameter PEEP/CPAP | 0 - 30 mbar |
Parameter Frequency | 2 - 200 1/min |
Display Size | 21 inch |
Minimum Order Quantity | 1 Piece |
Brand | BPL |
Model Name/Number | Elisa 300 |
Ventilation Modes | Expanded |
Patient Age Group | Paediatric, Adult |
Country of Origin | Made in India |
Screen Type | Touch Screen |
Screen Size | 12.1 inch |
Nebulization Type | Pneumatic |
Alarm View | 360 Degree |
Suction Routine | Automatic |
Optional Interface | CO2 |
Battery Backup | 2 Hours |
Minimum Order Quantity | 1 Piece |
Brand | Air Liquide |
Requirement Type | New |
Model Name/Number | Orion G |
Touch Screen Present | Yes |
Mounting Type | ICU |
Patient Age Group | Paediatric, Adult |
Country of Origin | Made in India |
Application | Intensive care respirator designed for resuscitation in the intensive care and the post-operative ro |
Patient Range | Adult, Child |
Patient Weight | 10 kg - 250 kg |
CE Marking | CE0459. The device complies with European requirements of Medical Devices Directive 93/42/EEC |
Medical Device Classification | Class IIb equipment, according to Directive 93/42/EEC |
Operating Temperature | +100 to +400 Degree Celsius |
Relative Humidity | 30% to 75% |
Atmospheric Pressure | 700 (3075 m) to 1060 m bar |
Storage Temperature | -400 to +500 Degree Celsius |
Storage Relative Humidity | 10% to 90% (at |
Storage Atmospheric Pressure | 500 (5550 m) to 1060 m bar |
Power Supply | 230VAC +-10% |
Frequency | 50 Hz |
Electrical Power Consumed | 120 VA |
Electrical Class | I , Type B |
Pneumatic Supply (O2 , Air) | (2.8 - 6 bar) / (280 - 600 kPa) |
Connection Standards Available | NF Connector |
Product DescriptionA ventilator is a life-saving equipment. This means that ICU staffs need real-time information in order to make the right decision. The Orion-G comes with a 7” TFT colour touch-screen that can display up to 4 curves, along with a host of monitored parameters. Also its highly responsive touch-screen and its encoder knob helps you choose and set your parameters in a safe, quick and easy way.
The Orion-G has three time-based curves and three loops which you require – P/V, P/F and V/F. Should you wish to analyze the patient’s progress, the Orion-G gives you the option to freeze the loop through its ‘Freeze’ function.
Designed for you
The Orion-G is a ventilator that is designed by you, for you. The graphical screen, the touch-setvalidate operation, the modes and the parameters are all designed keeping in mind your requirements for a ventilator that you can trust.
What’s more, the Orion-G is rugged and hassle-free, meaning that the biomedical team will find it easy to carry out all the necessary preventive maintenance interventions.
A Symbol of Quality
The Orion-G is a CE-marked ventilator. This carries with it the symbol of quality, which is unique to this segment.
Performance You Need:
Non-invasive ventilation
NIV with PS-PEEP is available as a dedicated function. NIV in Orion-G offers ventilation with leak compensation. The RSBI can also be monitored with ease during NIV.
Monitoring Parameters
The Orion-G gives you a range of monitoring parameters which will help you offer the best care for your patients. Weaning parameters like the Rapid Shallow Breath Index and the Occlusion Pressure provide you with the right information to take the right decision regarding the patient’s prognosis.
Advantages:
Touch-screen
Non-invasive mode
CE mark
Improved patient comfort
Minimum Order Quantity | 1 Piece |
Tidal Volume | 1 mL to 2600 mL |
Brand | BPL |
Model Name/Number | Elisa 600 |
Ventilation Modes | CPR, ALPV, PC-APRV, WOBOV, PAPS |
Patient Age Group | Adult, Neonatal, Paediatric |
Mounting Type | ICU |
Touch Screen Present | Yes |
Country of Origin | Made in India |
Minimum Order Quantity | 1 Piece |
Brand | Air Liquide |
Patient Age Group | Neonatal, Paediatric, Adult |
Ventilation Modes | VCV, PCV, PRVC, SIMV, PSIMV, PSV, CPAP, PS-PRO, DUO-LEVELS, PSP,CPAP,DUO-LEVELS, APRV |
Country of Origin | Made in India |
Requirement Type | New |
Model Name/Number | Monnal T75 |
Tidal Volume | 20 to 2000 ml |
Application | Intensive care respirator designed for resuscitation, intensive care and the postoperative room |
Weight | 3 to 250 kg |
CE Mark | CE 0459. The device complies with the European requirements in the Directive 93/42/EEC concerning me |
Medical Classification | Class IIb, according to Directive 93/42/CEE. |
Standards | ISO 14971 CEI 60601-1 CEI 60601-2-12 |
Electromagnetic Compatibility (EMC) | Complying with CEI 60601-1-2 (2001) |
Available Languages | French, English, Italian, German, Russian, Spanish, Lithuania, Polish, Czech,Portuguese and Chinese |
Size | H 35 x W 30 x D 40 cm |
Ventilator With Trolley | 16 kg - Ventilator 31,8 kg - Ventilator + trolley |
Operating Temperature | +10 to +40 Degree Celsius (+50 to +104 Degree Fahrenheit) |
Relative Humidity | 0 to 90 % (at 40 Degree Celsius without condensation) |
Atmospheric Pressure | 700 (3075 ) to 1060 mbar Altitude effect compensation |
Power Supply | 100-240 VAC +- 5 % |
Frequency | 50 - 60 Hz |
Product DescriptionMeeting your requirements Monnal T75 is the result of over 30 years experience in artificial patient ventilation. Its wide range of modes and its characteristics make it an ideal unit for the treatment of adult, child or infant patients. This ventilator combines both ease of use and patient comfort. It makes the work of the medical staff easier and can be used even in the most complex situations. The integrated turbine technology provides air autonomy adding enhanced mobility to the ventilator, while ensuring high-quality non-invasive ventilation.
High Flow Oxygen Therapy
Nasal High-Flow Oxygen Therapy delivers an accurate FiO range, while preserving moisture and temperature conditions of the lung similar to spontaneous breathing
Non Invasive Ventilation
Implementing non-invasive ventilation is a decisive step in patient''s acceptance of the treatment. Placing the mask and finding the most comfortable settings for the patient are amongst the challenges faced by carers.
Patient comfort is optimised with Monnal T75, the ventilator responds immediately to the efforts of patients in severe decompensation, through fine detection of patient triggers.
Turbine Technology
The combination of the turbine and the integrated proportional valves generate high flow rates, provide effective leaks management and meet patient needs while operating in a silence environment.
Nebulization
Bronchospasms can be managed more effectively using the nebuliser function, which keeps the same ventilation settings and ensures synchronisation of drug distribution during each patient inspiratory cycle.
Invasive Ventilation
Protective ventilation is required for critical patients. Monnal T75 provides support for carers in their treatment approach, from intubation to weaning and extubation.
Volumetric Capnography
In order to ensure the correct intubation of a patient and also to follow his metabolic progress, Monnal T75 CO2 sensor uses mainstream technology, providing immediate responses to carers. This function is used to monitor CO2 production, lung perfusion and alveolar ventilation with the following parameters: etCO2, VmCO2, Vmalv, Vdaw, Vdaw/Vt, CO2 slope